BKKWF - CHLORONATED SOLVENT T 74
- MSDS: BKKWF
- Manufacturer: AKZO COATINGS INC
- Product Name: CHLORONATED SOLVENT T 74
- National Stock Number: 6810-00N014238
Product Identification
Product ID:CHLORONATED SOLVENT T 74
MSDS Date:08/15/1989
FSC:6810
NIIN:00N014238
MSDS Number: BKKWF
Responsible Party
ORANGE, CA 92665
US
Emergency Phone: 313-589-3660; 313-855-7313
Info Phone: 513-433-4996
Cage: 98502
Contractor
Telephone: 714-637-1750; CHEMTREC 800-424-9300
Cage: 98502
Ingredients
AND ALUMINUM ALLOYS. DO NOT ALLOW CONTACT
RTECS: 9999999ZZ
SLOW HYDROLYSIS AND PRODUCES CORROSIVE ACID.
RTECS: 9999999ZZ
INGEST CAN CAUSE GI IRRIT, NAUS, VOMIT, &
RTECS: 9999999ZZ
SENSIT TO EPINEPHRINE. INTENTIONAL MISUSE BY DELIB
RTECS: 9999999ZZ
ASSOC RPTD/PRLNG OCCUP OVEREXP TO SOLVS W/PERM
RTECS: 9999999ZZ
SUGGESTED AS A CAUSE OF LIVER ABNORMALITIES/LUNG
RTECS: 9999999ZZ
ALUMINUM IS NOT AN ACCEPTABLE MATL OF
RTECS: 9999999ZZ
WILL BE USED TO HANDLE PRODUCT. DO NOT HANDLE UNTIL
RTECS: 9999999ZZ
NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENL
RTECS: 9999999ZZ
HEAT AND/OR UV RADIATION MAY CAUSE THE FORMATION OF
RTECS: 9999999ZZ
1,4-DIOXANE (DIETHYLENE DIOXIDE) (SARA III)
CAS: 123-91-1
RTECS: JG8225000
Fraction By Weight: <5%
OSHA PEL S, 100 PPM
ACGIH TLV: S, 25 PPM; 9293
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: >95%
OSHA PEL 350 PPM/450 STEL
ACGIH TLV: 350 PPM/450STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE IRRITANT, CNTCT MAY CAUSE
EYE BURNS/CORNEAL INJURY. INHAL OF VAPS/FUMES MAY CAUSE IRRIT OF
EYES, NOSE, THROAT, SLIGHT NARCOSIS, DIZZ. PRLNG/RPTD CNTCT MAY
CAUSE DERM, EYE IRRIT. EXCESS INHA L OF VAPS CAN CAUSE NASAL/ RESP
IRRIT, DIZZ, WEAK, FATG, NAUS, HDCH, POSS UNCON, EVEN
ASPHYXIATION.(SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:1,4-DIOXANE: IARC GROUP 2B.
Effects of Overexposure:HLTH HAZ: CHLOROCARBON/ CHLOROFLUOROCARBON(CFC)
MATLS HAVE PRDCD SENSIT OF THE MYOCARDIUM TO EPINEPHRINE IN LAB
ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS
(E.G.EPINEPHRINE) MAY BE CONT RAINDICATED EXCEPT FOR LIFE-
SUSTAININGUSES IN HUMANS ACUTELY/CHRONICALLY EXPOSED TO
CHLOROCARBONS/CFCS (SEE ING
Medical Cond Aggravated by Exposure:NONE EXPECTED.
First Aid
First Aid:INHAL: REMOVE TO FRESH AIR. GIVE ARTIFICIAL RESPIRATION IF
NECESSARY. SKIN: WASH WITH SOAP AND WATER. EYES: FLUSH WITH WATER
FOR AT LEAST 15 MINUTES, CONSULT MD. INGEST: DRINK ONE OR TWO
GLASSES OF WA TER TO DILUTE. DO NOT INDUCE VOMITING. CONSULT MD OR
POISON CONTROL CENTER IMMEDIATELY. TREAT SYMPTOMATICALLY.
Fire Fighting
Flash Point Method:TCC
Flash Point:>220F,>104C
Lower Limits:2.0
Extinguishing Media:FOAM, CO2, DRY CHEMICALS
Fire Fighting Procedures:H2O MAY BE INEFT. H2O SHOULD BE USED TO COOL
CNTNRS EXPOSED TO FIRE. FIRE FIGHT PERS SHOULD WEAR NIOSH/MSHA
APPRVD PRESS DEMAND SCBA & FULL PROT EQUIP .
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLOSED. ISOLATE FROM
HEAT, SPARKS, ELEC EQUIP, OPEN FLAME. CLOSED CNTNRS MAY EXPLODE
WHEN EXPOSED TO EXTREME HEAT. APPLICATN (SEE SUPP DATA)
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. AVOID
BREATHING VAPORS. VENTILATE AREA. REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT TAKE INTERNALLY. STORE CNTNRS
OUT OF SUN & AWAY FROM HEAT, SPARKS, OPEN FLAMES. CLOSE CNTNRS
AFTER EACH USE. CONSULT NFPA CODE FOR ADDNL STOR.
Other Precautions:USE APPRVD BONDING/GROUNDING PROC. OBSERVE LABEL
PREC. KEEP CLOSURES TIGHT & CNTNR UPRIGHT TO PVNT LEAKAGE. NEVER
USE PRESS TO EMPTY--DRUM IS NOT A PRESS VESSEL. AVOID BRTHG SANDING
DUST. DO NOT WELD/ FLAME CUT AN EMPTY DRUM. (SEE INGRED 09
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR DEVICE. SEE
SAFETY EQUIPMENT SUPPLIER FOR EVALUATION AND RECOMMENDATION. IN
CONFINED AREAS USE NIOSH/MSHA APPROVED AIRLINE RESPIRATOR OR HOOD.
Ventilation:SUFFICIENT VENTILATION TO KEEP VAP CONC BELOW GIVEN
TLV/LEL. FOR BAKING FINISHES, EXHAUST VAPS EMITTED ON HEATING.
Protective Gloves:IMPERVIOUS GLOVES
Eye Protection:CHEMICAL WORKERS GOGGLES
Other Protective Equipment:EYE BATH & SHOWER, CHEMICAL RESISTANT APRON,
BOOTS OR OTHER CLOTHING IF NEEDED TO AVOID RPTD/FREQ SKIN CONTACT.
Work Hygienic Practices:WASH HANDS BEFORE EATING, SMOKING OR USING
WASHROOM.
Supplemental Safety and Health
EXPLO HAZ: TO HOT SURFACES REQUIRES SPECIAL PRECAUTIONS. DURING
EMERGENCY CONDITIONS OVEREXPOSURE TO DECOMP PRODS MAY CAUSE HLTH
HAZ. SYMPTOMS MAY NOT BE IMMEDIATELY APPARENT. GET MD. THERMAL
DECOMP P RODUCTS MAY INCLUDE HCL & PHOSGENE . CNDTNS (STAB):
APPLICATION OF COATINGS CONTAINING HALOGENATED SOLVENTS.
Chemical Properties
HCC:T4
Boiling Pt:B.P. Text:165F,74C
Vapor Pres:SEE INGRED
Vapor Density:> AIR
Spec Gravity:1.318
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, BASES, OXIDIZERS, & ALUMINUM CMPDS. DO NOT USE HNDLG/STOR
EQUIP CONST W/METALLIC ALUMINUM (SEE INGRED 03)
Stability Condition to Avoid:WATER CONTAM. ALUMINUM CNTNRS, PUMPS,
PIPES. HIGH PRESS SPRAY EQUIP MADE OF ALUMINUM COMPONENTS FOR THE
(SEE SUPP DATA)
Hazardous Decomposition Products:THERMAL OR PYROLYTIC DECOMP WILL
PRODUCE CO, CO2, HCL, PHOSGENE, CHLORINE, SMOKE & NOX.
Disposal
Waste Disposal Methods:INCINERATE IN AN APPROVED FACILITY. DO NOT
INCINERATE CLOSED CONTAINERS. DISPOSE I/A/W FEDERAL, STATE AND
LOCAL POLLUTION CONTROL REQUIREMENTS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.